GF102

SKU : GF102

Price

400.00 USD


450.00 USD

 (-11%)
Quantity to buy
Total 400.00 USD

Do not have enough stock

Out of stock

GF102 PORTABLE SINGLE PHASE ENERGY METER TEST BENCH / Data Sheet : Download / Main CatalogsDownload

GF102 portable single phase energy meter testing bench used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage and current output. Widely used in lab and field, and then as single phase standard source.

FEATURES 

  • Meter under testing: 1P2W 
  • 2Testing mode: active power, reactive power 
  • Test 3pcs or 2pcs meter synchronously 
  • Start testing and creep testing 
  • Reference standard and power source integrated, easy to carry 
  • Measuring mechanical meter and electric meter 
  • Operating by manual keyboard or PC software 
  • With keyboard shortcuts 
  • Internal large capacity storage device for mass memory 
  • Local checking the testing result 
  • Overload, short circuit, open circuit protection 
  • With self-checking function

Electrical parameters 

  1. Accuracy class  : 0.05%, 0.1% 
  2. Power supply : One Phase AC 100-265V, frequency 50/60Hz. 

AC Voltage Output 

  1. Range : 57.7V, 100V, 220V, 380V; max 500V 
  2. Adjustment range : (0-120)%RG(1) 
  3. Adjustment fineness : 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. 
  4. Stability : 0.01%/120s 
  5. Distortion : 0.1% (Non-capacitive load) 
  6. Output load : max 25VA 
  7. Measuring accuracy : 0.05%RG 

AC Current Output 

  1. Range : 200mA, 1A, 5A, 20A, 100A; max 120A 
  2. Adjustment range : (0-120)%RG 
  3. Adjustment fineness : 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. 
  4. Stability : <0.01%/120s 
  5. Distortion : ≤0.1% (Non-capacitive load) 
  6. Output load : max 50VA 
  7. Accuracy : 0.05%RG 

Power Output  

  1. Active power output stability : <0.01%RG/120s 
  2. Reactive power output stability : <0.02%RG/120s 
  3. Active power measuring accuracy : 0.05%RG 
  4. Reactive power measuring accuracy : 0.1%RG 

Phase Output 

  1. Output adjustment range : 0°-359.999° 
  2. Output adjustment fineness : 10, 1, 0.1, 0.01 as optional. 
  3. Resolution : 0.01° 
  4. Accuracy : 0.05° 

Power Factor 

  1. Adjustment range : -1 ~ 0 ~ 1 
  2. Resolution : 0.0001 
  3. Measurement accuracy : 0. 0005 

Frequency Output 

  1. Adjustment range : 40Hz-70Hz 
  2. Output adjustment fineness : 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. 
  3. Resolution : 0.001Hz 
  4. Accuracy : 0.005Hz 

Voltage /Current/Harmonic Setting 

  1. Harmonic number : 2-51times 
  2. Harmonic content : 0-40% 
  3. Harmonic phase : 0-359.99 
  4. Harmonic setting accuracy : (10%±0.1%)RD(2) 

Power Energy Measurement Error 

  1. Active power energy : 0.05%RG 
  2. Reactive power energy : 0.1%RG 

Power Pulse Output 

  1. Power pulse type : active pulse, reactive pulse 
  2. Active power pulse output : 5V,10mA 

Power Pulse Input 

  1. Energy pulse type : support active and reactive pulse, the highest frequency 
  2. power pulse input is : 180K. 

Mechanical parameters 

  1. Dimensions (W×D×H) (mm) : 455x440x150 
  2. Weight (kg) :12 

Environmental conditions 

  1. Ambient temperature : -10°C to +40°C 
  2. Relative humidity : 35%-85% 

(1)RG means range, the same as below; 

(2)RD means the setted harmonic content, harmonic can be a single output,also multiple output. 



MOQ. 1Ea.




Visitors: 12,947,465