GF1021

SKU : GF1021

Price

400.00 USD


450.00 USD

 (-11%)
Quantity to buy
Total 400.00 USD

Do not have enough stock

Out of stock

GF1021 SINGLE PHASE PORTABLE ELECTRIC METER TEST EQUIPMENT / Data Sheet : Download / Main CatalogsDownload

GF1021 portable single phase energy meter test system used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage source and current source output. Widely used in lab and field, and then as single phase standard source. 

FEATURES 

  • Accuracy class 0.05 
  • 0-120A, 0-500V 
  • Test 3pcs or 2pcs meter synchronously 
  • Start testing and creep testing 
  • Reference standard and power source integrated 
  • Test by automatic or manual 
  • 7 inch TFT touch screen 
  • Weight light 8Kg 
  • Recorder 500 sets energy meter data 
  • Overload, short circuit, open circuit protection

Electrical parameters  

  1. Accuracy class  : 0.05%, 0.1% 
  2. Power supply : One Phase AC 85-265V, frequency 50/60Hz. 

AC Voltage output  

  1. Range : 57.7V, 100V, 220V, 380V; max 500V 
  2. Adjustment range : (0-120)%RG(1) 
  3. Adjustment fineness : 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. 
  4. Stability : 0.01%/120s 
  5. Distortion : 0.1% (Non-capacitive load) 
  6. Output load : max 30VA 
  7. Measuring accuracy : 0.05%RG 

AC Current output  

  1. Range : 200mA, 1A, 5A, 20A, 100A; max 120A 
  2. Adjustment range : (0-120)%RG 
  3. Adjustment fineness : 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. 
  4. Stability : <0.01%/120s 
  5. Distortion : ≤0.1% (Non-capacitive load) 
  6. Output load : max 50VA 
  7. Accuracy : 0.05%RG 

Power output  

  1. Active power output stability : <0.01%RG/120s 
  2. Reactive power output stability : <0.02%RG/120s 
  3. Active power measuring accuracy : 0.05%RG 
  4. Reactive power measuring accuracy : 0.1%RG 

Phase Output 

  1. Output adjustment range : 0°-359.99° 
  2. Output adjustment fineness : 10, 1, 0.1, 0.01 as optional. 
  3. Resolution : 0.01° 
  4. Accuracy : 0.03° 

Power factor 

  1. Adjusting range : -1 ~ 0 ~ 1 
  2. Resolution : 0.0001 
  3. Measurement accuracy : 0.0005 

Frequency Output 

  1. Adjustment range : 40Hz-70Hz 
  2. Output adjustment fineness : 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. 
  3. Resolution : 0.001Hz 
  4. Accuracy : 0.005Hz 

Voltage /Current/Harmonic Setting  

  1. Harmonic number : 2-51times 
  2. Harmonic content : 0-40% 
  3. Harmonic phase : 0-359.99 
  4. Harmonic setting accuracy : (10%±0.1%)RD(2) 

Power Energy Measurement Error  

  1. Active power energy : 0.05%RG 
  2. Reactive power energy : 0.1%RG 

Power Pulse Output 

  1. Power pulse type : active pulse, reactive pulse 
  2. Active power pulse output : 5V,10mA 

Power Pulse Input 

  1. Energy pulse type : support active and reactive pulse, the highest frequency power : pulse input is 180K. 

Mechanical parameters 

  1. Dimensions (W×D×H) (mm) : 325×275×135 
  2. Weight (kg) : 8 

Environmental conditions 

  1. Ambient temperature : -10°C to +50°C 
  2. Relative humidity : 35%-85% 

(1) RG means range, the same as below; 

(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. 


MOQ. 1Ea.


 